APS Small
Angle X-ray Scattering (SAXS) Beamlines
Ten different small-angle X-ray scattering (SAXS) beamlines are accessible
to the APS general user (overview). The combined capabilities of these beamlines span a
broad range of reciprocal space and X-ray photon energy allowing for investigations
from many disciplines of science including biology, materials science, environmental
science, chemistry, medicine, and physics. Coupled with a high data throughput
and fast time-resolved measurement capabilities, these instruments enable an
efficient use of the high intensity and high brilliance APS X-ray source. Some
of the beamlines have provided examples of their
data.
| Beamline |
Experiments |
Energy range (keV) |
Q range* (1/A) |
Operating Group |
Contact Person |
| 1-ID |
High Energy SAXS Simultaneous SAXS/WAXS |
50-100 |
0.005 - 0.4 & 1-10 |
XOR |
Jon Almer, 630-252-1049, Almer@aps.anl.gov |
| 5-BM |
High Energy SAXS |
5-65 |
0.008 - 20 |
DND |
Qing Ma, 630-252-0229, q-ma@northwestern.edu |
| 5-ID |
Simultaneous SAXS/WAXS
Windowless sample changer
Polymer stress-strain (Instron)
DSC (Linkam)
|
5-19 |
0.001 - 5 |
DND |
Steven Weigand, 630-252-0623, weigansj@northwestern.edu |
| 8-ID |
Coherent SAXS, grazing incidence coherent SAXS, time-resolved
SAXS, Grazing Incidence Small Angle X-ray Scattering (GISAXS) |
8-ID-I: 6.4-11.3 (generally fixed at 7.35 keV)
8-ID-E: 7.35 - 12 keV (GISAXS) |
0.0005 - 0.4 |
XOR |
Alec Sandy, 630-252-0281, asandy@aps.anl.gov
Suresh Narayanan, 630-252-0287, sureshn@aps.anl.gov
Michael Sprung, 630-252-0283, sprung@aps.anl.gov |
| 9-ID |
Pinhole set up, SAXS/ASAXS/WAXS, 2 circle goniometer |
5-20 |
0.001 - 1 |
CMC |
Diego M.Casa, 630-252-2033, dcasa@anl.gov |
| 12-BM |
SAXS, Solution scattering |
2.5- 28 |
0.008 - 1 |
BESSRC XOR |
Nadia Leyarovska, 630-252-8646, nadial@anl.gov |
| 12-ID |
SAXS/WAXS, ASAXS, Grazing incidence SAXS, Time-resolved SAXS |
4.8-25 |
0.0012 - 2.8 |
BESSRC XOR |
Soenke Seifert, 630-252-0391, seifert@anl.gov |
| 15-ID |
SAXS (Solution scattering) |
6-32 |
0.0012 - 2 |
ChemMat CARS |
David Cookson, 630-252-0468, cookson@cars.uchicago.edu |
| 18-ID |
SAXS/WAXS, static and time-resolved, Biological samples, solutions,
2D focused beam |
3.5 - 40 |
0.002 - 3.0 |
BioCAT |
Tom Irving, 630-252-0524, irving@biocat1.iit.edu
Liang Guo, 630-252-0508, lguo@bio.aps.anl.gov |
| 32-ID |
USAXS (1-D or 2-D), Anomalous USAXS, USAXS Imaging |
7 - 18 |
0.00015 - 1 |
XOR |
Jan Ilavsky, 630-252-0866, ilavsky@anl.gov
usaxs.xor.aps.anl.gov |
* Approximate Q ranges are given, depending
on conditions; contact the beamline for more information |